Input Parameters

W
Maximum DC power the inverter can handle
V
Maximum DC voltage the inverter can accept
A
Maximum DC current the inverter can handle
W
Rated power output of each PV module
V
Open circuit voltage of each PV module
A
Short circuit current of each PV module
%
Safety margin for temperature and degradation (5-15% recommended)

Results

Max Modules/String:
Max Parallel Strings:
Total Array Power: W
Enter your system specs to see results.

PV System Reference

PV System Configuration Guide

  • Max modules per string = ⌊(Vmax × (1 − margin)) ÷ Voc
  • Max parallel strings = ⌊(Imax × (1 − margin)) ÷ Isc
  • Total array power = modules per string × parallel strings × module power

Safety Margin Explanation

The safety margin accounts for temperature, module degradation, and voltage fluctuations. Commonly 5–15%.

String Voltage Considerations

String voltage varies with temperature. Cold conditions increase Voc, so design for worst-case winter temperatures to avoid exceeding inverter limits.

Module Matching